Mobile Home Installation
The Morsø 7600 can be installed in a mobile home if equipped with an outside combustion air kit, a
terminal cap with a spark arrestor, and if it meets the following installation requirements:
The stove must be secured to the mobile home structure by bolting through the hearth pad and
into flooring.
7642 & 7644 are prepared for securing.
The 7648 requires you drill three holes in the floor at specific points (see diagram below).
The stove must be installed with a listed Type HT chimney connector, HT Chimney, and termi-
nal cap with spark arrestor. Never use a single wall connector (stovepipe) in a mobile home
installation.
Floor protection requirements in section 1.5 must be followed precisely.
In Canada, this appliance must be connected to a 6” (152 mm) factory-built chimney confor-
ming to CAN/ULC-629M, STANDARD FOR FACTORY BUILT CHIMNEYS. Floor protection as
referenced in section 1.5 must be followed, as well as use of Canadian Floor Protector.
Follow the chimney and chimney connector manufacturer’s instructions when installing the
flue system for use in a mobile home.
Intake air piping can be installed through the oor into a vented crawl space or through the
wall of the residence to obtain outside air.
Install in accordance with 24 CFR, Part 3280 (HUD).
NOTE: Top sections of chimney must be removable to allow maximum clearance of 13.5” from
ground level for transportation purposes.
3
8
"
8 mm
3
8
"
8 mm
3
8
"
8 mm
0
3
7
8
"
97 mm
7
5
8
"
195 mm
0
6
5
8
"
168 mm
6
5
8
"
168 mm
Revisions
Rev.
Sign.:
Title:
Drawing no.:
Dim. without indication of margin acc. to DS/ISO 2768-1 m
1:2.5
Boreanvisning for evt. fastmontering
Drilling instructions for potential fixing
Morsø 7600
RSV
21.11.2008
A3
Work up Drawing
9,98 kg
Cast Iron GG15
Date of print: 29-09-2010
C:\UDV\tegninger\7600\7600-16 Pedistalfod.SLDPRT
7616
Itemno.:
This drawing is Morsø Jernstøberi A/S' property and must not be sold, lended or copied without any written authorization from the company.
Material:
Weight:
Model no.
Drawingtype:
Location of file:
Scale:
Format:
Released:
Construction:
Date:
Borefixturer:
7600-16 a
Page: 3
WARNING:
NEVER DRAW COMBUSTION AIR FROM A WALL, FLOOR OR CEILING CAVITY OR FROM ANY ENCLOSED
SPACE SUCH AS AN ATTIC OR GARAGE.
DO NOT INSTALL IN A BEDROOM OR A ROOM WHERE PEOPLE SLEEP.
CAUTION:
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEILING/ROOF MUST BE
MAINTAINED (I.E., DO NOT CUT THROUGH FLOOR JOIST, WALL STUD, CEILING TRUSS, ETC.)
Acid Protection
If acid-washing the masonry around the stove, protect the stove surface with an acid-proof cover.
Outside Air Supply
Only mobile home approved heaters may be installed into mobile homes and it is a requirement that
outside air is supplied directly to the heater.
However, in every residential situation where the room has poor air infiltration via doorways, windows
and the like, providing a dedicated outside air supply may be required. By attaching a non-combustible
conduit (ducting) directly to the air intake of the heater, outside air can be delivered directly to the com-
bustion chamber. Some models may require an additional (optional) outside air kit. The conduit used for
providing outside air should have a free space equal to but no less than 3” diameter.
Outside air is particularly important when the heater is to be installed into a well sealed room, or where
an extractor hood or ventilation system interferes with the room’s natural air pressure. Avoid placing
the outside air supply onto a wall that that is usually subject to negative pressure from normal wind
pattern.
A
A
A-A
STORM COLLAR
EMBASE TEMPÉTE
SPARK ARRESTOR
PARE ÉTINCELLES
LISTED CHIMNEY
CHEMINÉE REPERTORIÉE
ROOF FLASHING/SUPPORT
SOLIN TOUT/SUPPORT
lISTED CHIMNEY
CONNECTOR
CONDUIT CHEMINÉE
RÉPERTORIE
OUTSIDE AIR
EXTÉRIEUR AIR
FLOOR PROTECTOR
PROTECTION DU SOL
Revisions
Rev.
Sign.:
Title:
Drawing no.:
1:15
Skorstenskitse
Morsø 7600
RSV
20.05.10
A4
268,91 kg
Date of print: 25-05-2010
U:\udv\Tegninger\TILBEHØR\Skorsten\Ovn med skorsten til vejledning.SLDASM
7600-125 a
Itemno.:
This drawing is Morsø Jernstøberi A/S' property and must not be sold, lended or copied without any written authorization from the company.
Material:
Weight:
Model no.
Drawingtype:
Location of file:
Scale:
Format:
Released:
Construction:
Date: